Before-image Buffers (-bibufs)

Operating system
and syntax
UNIX
Windows
-bibufs n
Use
with
Maximum value
Minimum value
Single-user default
Multi-user default
DBS
3
20

n

The number of before-image buffers.

Use Before-image Buffers (-bibufs) to specify the number of before-image buffers. This parameter is useful only when running the before-image writer (BIW). The BIW continually writes the filled before-image buffers to disk, making the buffers available to other client and server processes. Without a BIW writing the buffers, any gain from increasing the number of buffers is negligible.